viewed: 日期:2016/4/14 15:25:15
At 1 o’clock of March 27th, 2016, Inner Mongolia Energy Xingan 2*340 #2 unit flue gas desulfurization devices, which was contracted to build by our company, smoothly passed the 168 hours test. The parameters and indicators are meeting the standards.
At 1 o’clock of March 20th, #2 unit desulfurization system was started. Until At 1 o’clock of March 27th, the flue gas bypass baffle was shuttled down and flue gas desulfurization started. It was entered into the formal 168 hours trial operation. During the trial operation, the unit average load was 300 MW, the operation rate was 100%, average desulfurization efficiency was 97.3% and automatics and protection rate was 100%. The main operation parameters were controlled in the designing scope. At present, the main and auxiliary equipment of #2 unit desulfurization system operates well, operation parameters keep stale and all directors meet the designing requirement.
The project was started in 2012. The project management consistently put the safe and quality at the first place by strictly control safety, quality and process. The whole staff overcame the difficulties, such as short schedule, heavy tasks, low temperature and deficient capital to ensure #2 units desulfurization devices putting into operation in safe and high quality.